Forum Post: RE: Thermal transient behavior of INAs and OPAs
Ken,pls see the corrected plotVBR,Kavindu
View ArticleForum Post: RE: Difference between IDD and Is Current in Operational Amplifier
Hello Mr. Ron Michallick, Thank you for your replyIn the Part LM2904 MWC MCD0950A, may i know what MWC MCD0950A represents to?. Shall i take the Die Size in the link...
View ArticleForum Post: RE: how to remove 2Volt offset?
Thanks,Yourcouncils have beenvery helpful.The application workscorrectly.My application is the conditioning and the processing of the output signal from a strain gauge bridge of a load cell.I would...
View ArticleForum Post: RE: Difference between IDD and Is Current in Operational Amplifier
Prasath,I am not familiar with SVA die sales. I suggest starting a new thread with LM2904M part number in the post subject.Die sizes can vary significantly. The package only limits the maximum die size.
View ArticleForum Post: RE: Thermal transient behavior of INAs and OPAs
Kavindu,I am not clear what the CVin vertical axis on your graph show - there is no such label on your schematic (see below) and with the componets values you use there is no node with potential around...
View ArticleForum Post: RE: INA2332: huge gain difference
Hello Tobias,Here are a couple suggestions:1) Try replacing the load cell with a known differential voltage. Given that your gain is 1000V/V and 550mV<Vcm<3.8V when Vs=5V, a 2mV differential...
View ArticleForum Post: OPA4344 / Input offset voltage
Hi,Our customer has understood about the behavior/specification of OPAx344 as following description.It seems they referred "Fig.2 - Simplified schematic" on the datasheet -page9. - OPAx344 has 3...
View ArticleForum Post: Wireless Mobile Charger
I needed 18V 1A 100KHZ sinewave signal. How to get this ? Now i am using a 55 timer for generating 100KHZ but the output current is very low so how to get high output current... Please help me soon
View ArticleForum Post: RE: Thermal transient behavior of INAs and OPAs
Thank you all for your attention on this regards and sorry if I'm keep on confusing you. Actually the CVin corresponds to the out2 of the schematic and the front end of the INA is fed by a Strain gauge...
View ArticleForum Post: what MWC MCD0950A represents to?
Hello,In the Part LM2904 MWC MCD0950A, may i know what MWC MCD0950A represents to?. Shall i take the Die Size in the link http://www.ti.com/lit/ml/snao363/snao363.pdf for LM2904M part number. And in...
View ArticleForum Post: low input bias current Op-amp for accelerometers' charge amplifier
Dear experts,I am designing charge amplifier cuicuit to convert charge to voltage output for accelerometers' aquisition circuit.Sensitivity of the charge amplifier is 10pc/g. I want a sensitivity of...
View ArticleForum Post: Help with INA333 ECG Circuit
I've attached the TINA-TI circuit I've been working on. Im no expert in the electronics field or the medical engineering so I am having a hard time figuring out how to construct my ECG circuit. This...
View ArticleForum Post: RE: OPA4344 / Input offset voltage
Sonoki,Both input differentia pairs are trimmed to zero at the wafer level but the die packaging-related stress causes a random Vos shift in both (a) and (c) modes. Mode (b) is a 400mV Vcm transition...
View ArticleForum Post: Two Thermoucouple circuits interfering with each other
Hi I have a circuit board which has inputs for two thermoucouple K_type clamps. They are fed into two seperate INA126 amplifiers that run off +5V. The front end is biased to 2.5 volts to keep the...
View ArticleForum Post: Internal reference voltage of INA209/219
Hi BU teamwould you share me the internal reference voltage of INA209/219?Couldn't find the information in datasheet.thanks
View ArticleForum Post: RE: programmable gain amplifier
Hi,Thanks for the quick response.If I use a voltage divider,what about a type B thermocouple?Type B thermocouple has negative voltage values upto 39°.Regards,Divya
View ArticleForum Post: load cell signal conditioning
Hi,I am in the process of designing loadcell. . I am using a Wheatstone bridge circuit to detect the difference in my voltages with the weight differences. I am using two strain gauges both 350 ohm...
View ArticleForum Post: RE: load cell signal conditioning
Hi, Jayanthi It looks like you build your circuit like Fig 5 in the datasheet. Can you share your schematic so we can check them for correctness? It helps if you provide PCB too.From the structure of...
View ArticleForum Post: RE: how to remove 2Volt offset?
Hello Antonino,Can you please share the data sheet of your load cell? I don't understand why a 4-channel instrumentation amplifier is required. I found a document that may be of...
View ArticleForum Post: RE: LM4041
Winston,Yes it can be used as an amplifier except the common ("ground") pin is the cathode. For the TL431 the common pin is the anode. Therefore the LM4041 is easiest to use in a negative...
View Article